摘要
在電子構裝散熱中,為了降低散熱模組與發熱源的表面接觸熱阻,故需要使用熱介面材料(Thermal Interface Material, T.I.M.)把CPU所產生的高熱有效的帶走以達到散熱的目的,本實驗室所開發建立一套熱介面材料量測系統,此系統可精準量測出熱介面材料之性質。本論文主要目的在藉由此一熱介面材料量測系統量測分析導熱膠片與絕熱材料之熱傳導性質。絕熱材料已是能源開發、節約工程的重要組成,是與生態、環境保護和可持續發展密切相關的行業,針對絕熱材料之熱傳導性質分析研究對未來能源工程必然是重要的依據。實驗結果在Thermal Grease與Thermal Pad上都有相當好的準確性,故利用此一熱介面材料量測系統量測分析絕熱材料之熱傳導性質,在理論模組建立上可避免因絕熱材料之表面接觸熱阻造成測量結果的影響並且求得該材料之真實熱傳導係數。
本論文實驗分為三大部分:第一部分為T.I.M.量測平台的穩定性分析,第二部份為利用T.I.M.量測平台實驗分析Thermal Pad之熱傳導性質,第三部份為利用T.I.M.量測絕熱材料熱傳導性質實驗分析。
由實驗結果可以發現, 在Thermal Grease量測部分T.I.M.量測平台所量測出道康寧TC-5121及信越7762熱傳導係數重複性相對誤差皆在1%以下。在Thermal Pad量測部分利用SAINT-GOBAIN先進材料公司所委託14種樣品,以及崇越科技的1種樣品測試,在這15個樣品測試中重複性與再線性相對誤差皆在10%以下,故本量測平台具有良好的穩定性與準確性。因此使用此量測平台測量絕熱材料之熱傳導性質。利用已知性質之電木、鐵氟龍等材料測量進行比對,絕熱材料在控制不同厚度下所量測之材料熱阻值亦有所不同,隨著材料厚度增加其所對應之總熱阻值相對遞增,由實驗結果得知若將絕熱材料試片厚度控制在1.5mm以下時,T.I.M.量測平台所測量出的絕熱材料之熱傳導係數與文獻參考值之相對誤差皆在10%以下,顯示此一熱介面材料量測系統無論在導熱膠片及絕熱材料量測上,皆具有相當好的穩定性與準確性。
Abstract
In order to reduce the thermal resistance contact from thermal modules and heat source, we need to use thermal interface material (Thermal Interface Material, TIM) to effectively remove the heat which is generated by the CPU and achieve the purpose of cooling. Developed in our laboratory, we establish a measurment system for the measurment of thermal interface materials. This system can accurately measure the properties of thermal interface materials. The main purpose of this paper is to gauge and analyze the thermal conductivity of thermal pad and insulation materials by using the TIM measurment system. Thermal conductivity analysis of insulation materials must be a very important basis of energy engineering in the future.
The results can be found in the following experiments. The relative error of thermal conductivity’s repeatability were less than 1% when measuring Thermal Grease ( using Dow Coning TC-5121 and Shin-Etsu 7762 ) by TIM measurement system. When measuring 15 kinds of Thermal Pad’s thermal conductivity ( using 14 kinds of samples from the SAINT-GOBAIN Advanced Materials (Taiwan) Co.,Ltd and one from the TSC ).We can found that the relative error of repeatability and reproducibility were below 10%. As mentioned above, TIM measurement system has high stability and accuracy. Therefore, we use TIM measurement system to gauge and analyze the thermal conductivity of insulation materials. Measure and compare some materials, such as bakelite and teflon, which their thermal conductivity properties had been known. The experimental results shows that we control the thickness of insulation material below 1.5mm, the relative error of thermal conductivity which was gauged by the TIM measurement system, and the theoretical value will less than 10%. These results also indicated that this TIM measurement system have high stability and accuracy in measureing Thermal Pad and insulation materials.
參考文獻
[1] 賴美錵,「擴散熱阻於電子構裝之分析與應用」,碩士論文,元智大學機械工程研究所,2000。
[2] Ashay Dani,James C,Jr. Matayabas, Paul Koning,”THERMAL INTERFACE MATERIAL TECHNILOGY ADVANCEMENTS AND CHALLENG-AN OVERVIEW”, Intel Corporation Assembly Technology Development 5000,W.Chandler Blvd Chandler,AZ 85226.
[3] 黃振東、張志忠,「熱界面材料的發展現況與專利分析」,熱管理產業通訊,第2期。
[4] M. Grujicic, C. L. Zhao, E. C. Dusel, “The Effect of Thermal Contact Resistance on Heat Management in the Electronic Packaging”, Applied Surface Science, 2005.
[5]ASTM C177-97, Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus, West Conshohocken, PA.
[6]ASTM D374, Standard Test Methods for Thickness of Solid Electrical Insulation Materials, American Society for Testing and Materials, West Conshohocken, PA.
[7]ASTM D5470-01, Standard Test Methods for Thermal Transmission Properties of Thin Thermally Conductive Solid Electrical Insulation Materials, American Society for Testing and Materials, West Conshohocken, PA.
[8]ASTM E1225-99, Standard Test Method for Thermal Conductivity of Solid by Means of Guarded-Comparative-Longitudinal Heat Flow Technique, West Conshohocken, PA.
[9]傅裕修,「熱介面材料(T.I.M.)之K值測定與靈敏度分析」,碩士論文,清華大學工程與系統科學研究所,2006。
[10] 許玲玲、葛菁,”我國絕熱材料業發展現狀”,Aug 2005。
[11] 許毅帆,「熱介面材料(T.I.M.)測試平台之不準度分析」,碩士論文,清華大學工程與系統科學研究所,2007。
[12] 鐘昌宏,「高K值之熱界面材料研發」,碩士論文,清華大學工程與系統科學研究所,2008。