研究生: |
邱日湘 Chiu, Jih-Hsiang |
---|---|
論文名稱: |
以肌電訊號回授控制動力下肢輔具及實現上下樓梯與行走 A Powered Lower Limb Orthosis based on Electromyogram Signals Feedback Control and Implement Ascending and Descending and Walking |
指導教授: |
陳建祥
Chen, Jian-Shiang |
口試委員: |
曹哲之
Tsao, Che-Chih 林明璋 Lin, Ming-Zhang |
學位類別: |
碩士 Master |
系所名稱: |
工學院 - 動力機械工程學系 Department of Power Mechanical Engineering |
論文出版年: | 2017 |
畢業學年度: | 106 |
語文別: | 中文 |
論文頁數: | 70 |
中文關鍵詞: | 動力下肢輔具 、肌電訊號 |
外文關鍵詞: | Powered Limb Orthosis, Electromyogram |
相關次數: | 點閱:6 下載:0 |
分享至: |
查詢本校圖書館目錄 查詢臺灣博碩士論文知識加值系統 勘誤回報 |
本文主要針對下肢能正常產生肌電訊號者,利用肌電訊號作為外回授控制穿戴式人體下肢輔具。透過改善輔具機構設計,將輔具實體部分重量傳至地面,減輕重量對穿戴者造成的負擔。在站到坐及坐到站系統中,加入了電池重量與摩擦力的補償,以及加入控制器做回授控制,提升輔助效果。上下樓梯時,根據支撐期及擺盪期的肌電訊號給予輔助力。由實驗結果得知,上樓梯支撐期左右腳股直肌輔助比為45.53%及54.78%,擺盪期左右腳脛前肌為65.16%及57.92%;下樓梯支撐期股直肌及脛前肌輔助比為57.86%及65.69%,擺盪期股直肌及脛前肌為55.91%及78.66%,可知股直肌及脛前肌都是省力。走路時,分為支撐期與擺盪期,根據足底壓力、股直肌與脛前肌肌電訊號的特性,建立一套走路動作意向偵測方程式。
輔具為外骨骼狀穿戴於下肢外側,於膝關節及髖關節分別裝置無刷馬達作為致動器,並以電池作為動力來源,藉由馬達轉動帶動輔具進而給予穿戴者輔助力,使穿戴者在進行起立及坐下的動作時能減少出力,以達到輔助之目的。
This paper designed a lower limb exoskeleton system for the people who can generate electromyogram functionally. Through the improvement of mechanism design which can transfer partial orthosis weight to ground and reduce the orthosis weight burden that impact on the wearer. For stand to sit and sit to stand system, we add the battery weight compensation and friction compensation, and do feedback control with controller. For ascending and descending, giving the auxiliary force according to the EMG in stance phase and swing phase, then we can find out rectus femoris and tibialis anterior both achieve energy-saving in stance phase and swing phase from the experimental results. For walking, the walking gait can be separated into stance phase and swing phase. According to foot pressure and electromyogram of rectus femoris and tibialis anterior, we establish an algorithm to estimate motion intention while walking.
This exoskeleton is actuated by four flat EC motors on the wearer’s both knees and hips. Through the rotation of motors, it sends torque to wearer’s knees and hips in order to reduce the strength when sitting,standing, ascending and descending.
[ 1 ] Nicholas Yagn, “Apparatus for facilitating walking, running, and jumping,” U.S.Patents 420 179, 1890.
[ 2 ] bleex.me.berkeley.edu/research/exoskeleton/bleex/
[ 3 ] bleex.me.berkeley.edu/research/exoskeleton/elegs%E2%84%A2/
[ 4 ] intl.eksobionics.com/
[ 5 ] sanlab.kz.tsukuba.ac.jp/?page_id=51
[ 6 ] S. Zhou, D. Lawson, W. Morrison, and I. Fairweather, “Electromechanical delay in isometric muscle contractions evoked by voluntary, reflex and electrical stimulation, ”European Journal of Applied Physiology and Occupational Physiology, vol. 70, 1995, pp. 138-145.
[ 7 ] X.-g. Xi and W.-g. Li, “Study of Proportional Control Electromyography Prosthetic Hand, ” in Electrical and Control Engineering (ICECE), 2010. International Conference on, 2010, pp. 2055-2058.
[ 8 ] M. Kanthi, I. S. V. Karteek, H. S. Mruthyunjaya, and V. I. George, “Real-time control of active ankle foot orthosis using LabVIEW and Compact-RIO, ” in Biomedical Engineering (ICoBE), 2012 International Conference on, 2012, pp. 296-299.
[ 9 ] Hsien-Yung Huang, Toward the Gait Analysis and Control of a Powered Lower Limb Orthosis in Climbing and Descending, Master Thesis , National Tsing Hua University, Department of Power Mechanical Engineering, 2012.
[ 10 ] Shao-Hwei Tseng, Biofeedback of A Lower-Limb Orthoses, Master
Thesis , National Tsing Hua University, Department of Power Mechanical Engineering, 2011.
[ 11 ] Chang-Jin Yu, Motion Detection for Paraplegic Patients with a Powered Lower Limb Orthosis in Ascending and Descending, Master Thesis, National Tsing Hua University, Department of Power Mechanical Engineering, 2014.
[ 12 ] Chuan Yang, Electromyogram Signals Feedback Control Applied in a Powered Lower Limb Orthosis, Master Thesis, National Tsing Hua University, Department of Power Mechanical Engineering, 2016.
[ 13 ] Saiwei Yang, EMG-Electromyography, National Yang-Ming University
[ 14 ] M.B.I Raez, M.S. Hussain, and F. Mohd-Yasin, “Techniques of EMG signal analysis: detection, processing, classification and applications ” 2006, pp.12-32.
[ 15 ] smpp.northwestern.edu/bmec66/weightlifting/emgback.html#emgsig
[ 16 ] Yi-Jhen Li, An Active Lower Limb Orthosis based on Electromyogram Signals, Master Thesis, National Tsing Hua University, Department of Power Mechanical Engineering, 2015.
[ 17 ]www.analog.com/media/en/technical-documentation/data-seets
/ADXRS610.pdf
[ 18 ] www.memstec.com.tw/product.php?pid=135
[ 19 ] Maxon, "flat EC motror datasheet"
[ 20 ] www.maxonmotor.com.tw/maxon/view/product/motor/ecmotor/ecflat
/ecflat90/244879
[ 21 ] www.harmonicdrive.net
[ 22 ] Maxon, "EPOS2-Communication-Guide," 2013
[ 23 ] www.maxonmotor.com.tw/maxon/view/product/control/Positionierung
/375711
[ 24 ] www.alibaba.com/product-detail/shuangye-high-quality-36v-12ah-
bottle_1090522936.html
[ 25 ] www.mathworks.com/products/sysid/
[ 26 ] www.mathworks.com/discovery/pid-tuning.html
[ 27 ] Jacob E Earp, Robert U Newton, Prue Cormie, Anthony J Blazevich, “Knee angle-specific EMG normalization: The use of polynomial based EMG-angle relationships,” Journal of Electromyography and Kinesiology, Vol. 23 No. 1, 2013, pp. 238-244.
[ 28 ] Min Lei, Zhizhong Wang, Zhengjin Feng, “Detecting nonlinearity of action surface EMG signal,” Physics Letters, Section A: General, Atomic and Solid State Physics, Vol. 290 Issues 5-6, 2001, pp. 297-303.
[ 29 ] J. E. Zachazewki, P. O. Riley, D. E. Krebs, “Biomechanical analysis of body mass transfer during stair ascent and descent of healthy subjects,” Journal of Rehabilitation Research and Development, Vol. 30 No. 4, 1993, pp. 412-422.
[ 30 ] Yan Tingfang, Cempini Marco, Oddo Calogerol Maria, Vitiello Nicola, “Review of assistive strategies in powered lower-limb orthoses and exoskeletons, ” ROBOTICS AND AUTONOMOUS SYSTEMS, Vol. 64, 2015, pp.120-137.
[ 31 ] Wei Meng, Quan Liu, Zude Zhou, Qingsong Ai, Bo Sheng, Shengquan (Shane) Xie, “Recent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation ”Mechatronics, Vol.31, 2015, pp.132-145.