研究生: |
陳復生 |
---|---|
論文名稱: |
半導體廠SEM作業員視覺疲勞之評估改善 Improving the Eye Fatigue Problem of SEM Operators in Semiconductor Industry |
指導教授: | 王茂駿 |
口試委員: | |
學位類別: |
碩士 Master |
系所名稱: |
工學院 - 工業工程與工程管理學系碩士在職專班 Industrial Engineering and Engineering Management |
論文出版年: | 2006 |
畢業學年度: | 94 |
語文別: | 中文 |
論文頁數: | 66 |
中文關鍵詞: | 掃瞄式電子顯微鏡 、視覺疲勞 、閃光融合閥值 、近點調節值 |
外文關鍵詞: | Scanning Electron Microscope (SEM), eye fatigue, critical fusion frequency (CFF), near point accommodation (NPA) |
相關次數: | 點閱:2 下載:0 |
分享至: |
查詢本校圖書館目錄 查詢臺灣博碩士論文知識加值系統 勘誤回報 |
在晶圓製造過程中,掃瞄式電子顯微鏡工作站(SEM)為主要晶圓檢測作業之一。由於SEM作業員需要長時間注視螢幕導致視覺疲勞的問題。本研究評估LCD螢幕尺寸(14吋、19吋)及晶圓有無鍍金對客觀視覺疲勞指標(NPA、CFF)、主觀視覺疲勞評比與作業績效的影響。本實驗共有12位SEM作業員參與並於無塵室中進行。實驗結果發現當晶圓樣本加以鍍金後有助於降低SEM作業對NPA閾值與CFF閾值的影響。使用19吋的LCD螢幕的情況下,除了能降低客觀視覺疲勞,更可降低主觀視覺疲勞程度及提升作業績效。因此建議使用19吋LCD螢幕及鍍金晶圓以改善作業員之視覺疲勞問題。
關鍵詞:掃瞄式電子顯微鏡、視覺疲勞、閃光融合閥值、近點調節值
Scanning Electron Microscope (SEM) station is one of the main inspection tasks in the wafer manufacturing process. Because of searching on the screen for long time, SEM operators frequently complained about visual fatigue problems. In this study, we evaluated the effects of LCD monitor size (14 and 19 inch) and wafer coating condition (non-coating wafer and gold-coated wafer) on objective visual fatigue (NPA and CFF), subjective eye fatigue rating and task performance. Twelve SEM operators participated in this study and conducted the experiment in fab. The results indicate that the gold-coated wafer had significant reduction on NPA and CFF threshold change. Using a 19-inch LCD not only reduced objective visual fatigue but also reduced subjective eye fatigue and improved task performance. It is recommended to use a 19-inch LCD monitor and gold-coated wafer to improve SEM operators’ visual fatigue problems.
Keywords: Scanning Electron Microscope (SEM), eye fatigue, critical fusion frequency (CFF), near point accommodation (NPA)
1. 陳忠助,(1995),螢幕類型與作業特性對視覺績效及視覺疲勞影響之研究。國立台灣科技大學碩士學位論文。
2. 黃琪雯,(2001),電腦工作站螢幕大小設計之探討,私立中原大學工業工程學系碩士學位論文。
3. Bullimore, M. A., Fulton, E. J. and Howarth, P. A. (1990). Assessment of visual
Performance, In Evaluation of human work: A practical ergonomics methodology,
Wilson. J. R. and Corelett E. N. (eds.), Taylor and Francis, London.
4. Chi, C. F. and Lin, F. T. (1998). A comparison of seven visual fatigue assessment techniques in three data-acquisition VDT tasks. Human Factors, 40, pp. 577-590.
5. Ferguson, D.A., Major G. and Keldoulis T. (1974). Vision at work, visual defect and the visual demand of tasks, Applied Ergonomics, 5, 84-93.
6. Fisher, R. F. (1974). The force of contraction of human ciliary muscle during accommodation. Journal of physiology, 270, pp. 51-74.
7. Grandjean, E., Hunting,W. & Pidermann, M., (1983).“VDT workstation design: preferred settings and their effects,” Human Factors, 25(2): 161-175 .
8. Gunnarsson E., and Soderberg I. (1983). Eye strain resulting from VDT work at the Swedish Telecommunications Administration. Applied Ergonomics, 14, pp. 61-69.
9. Haider, M., Kundi, M., and Weissenbock, M. (1982).“Worker strain related to VDUs with differently colored characters,” In Grandjean, E. & Vigliani, E. Eds. “Ergonomic Aspects of Visual Display Terminals,”: Taylor & Francis, London: 53-64
10. Hallett, P. E. (1986).“Eye movements,” In Boff,K.R., Kaufman,L. & Thomas,
J.P.(eds), “Handbook of Perception Human Performance, Volume 1:10.1-10.100 .
11. Horie, Y. (1994). Prevention of visual fatigue in workstation, Proceedings of the
1st Human Factors Association Conference in Taiwan, National Tsing Hua
university.
12. Harris, D.H. (1969). The nature of Industrial Inspection, Human Factors, 11(2),
139-148.
13. Ishihara, S., Miyao, M., Tamura, H., Iguchi, H. and Furukawa, K., (1987).
“ Effects of CRT display on pupil area, Proceedings of the third symposium on
human computer interface,” Osaka:203-194.
14. Ishikawa, S., (1990).“Examination of the near triad in VDU operators,”
Ergonomics, 33(6) :87-798 .
15. Iwasaki, T., and Akiya, S. (1991). The significance of changes in CFF values
during performance on a VDT-based visual task. In M. Kumashiro & E. D.
Megaw (Eds.). Towards human work: Solutions to problems in occupational
health and safety, Taylor and Francisl, London, pp. 352-357.
16. Megwa, T. (1990). The definition and measurement of visual fatigue, In: J. R.
Wilson and E. N. Corlett (Eds.), Evaluation of human work, Taylor and Franics,
London, pp. 682-702.
17. Menozzi, M., Lang, F., Napflin, U., Zeller, C. and Krueger, H. (2001). CRT
versus LCD : effects of refresh rate, Display, 22, 79-85.
18. Moclair, F.M. and Gallwey, T.J. (1998). Memory load and decision aids in
inspection of silicon wafers. Proceeding of 13th Congress of the International
Ergonomics Association, Tampere, Finland, June 29th-July 4, 1, 226-228.
19. Saito,S., Noro,K., (1990). “Visual ergonomics in Japan,”Ergonomics, VOL.33,
NO.6, :657.
20. Saito, S., Taptagaporn, S., and Salvendy, G.. (1993). “Visual comfort in using
different VDT screens,” International Journal of Human-Computer Interaction,
5(4) :313-323.
21. Sanders, M. S. and McCormick, E. J. (1998). Human factors in engineering and
design, 7th edition, McGraw-Hill, New York.
22. Satoru, K. (1997). Ergonomic comparison of liquid crystal display and cathode
ray tube display. Display and Imaging, 5(3), 181-190.
23. Shieh, K. K. (2000). Effects of reflection and polarity on LCD viewing distance,
International Journal of Industrial Ergonomics, 25, 275-282.
24. Sinclair, M. A. (1990). Subjective assessment. In Evaluation of human work,
Wilson J. R. and Corlett, E. N. (eds.), Taylor and Francis, London, pp. 58-88.
25. Smith, G. L. and Adams, S. K. (1971). Magnification and Microminiature
Inspection, Human Factors, 1971, 13(3), 247-254.
26. Taptagaporn, S., Saito, S. (1990). “How Display polarity and lighting conditions
affect the pupil size of VDT operators,” Ergonomics, 33(2), pp.201-208 (1990).
27. Wang, M. J. J. and Huang, C. L. (2004). Evaluating the eye fatigue problem in
wafer inspection. IEEE Transactions on Semiconductor Manufacturing, 17, pp
444-447.
28. Weber, A., Jermini, C. and Grandjean, E. P. (1975). Relationship between
objective and subjective assessment of experimentally induced fatigue,
Ergonomics, 18,pp.151-156.
29. Yoshitake, H. (1975), Relation between the symptoms and the feeling of fatigue,
In Methodology in Human Fatigue Assessment, Hashimoto, K., Hashimoto, K.,
Kogi, K. and Grandijean, E. (eds.), Taylor and Francis, London, pp.175-186.
30. Zhu, Z. and Wu, J. (1990);“On the standardization of VDT’s proper and optimal
contrast range,” Ergonomics, 33(7):925-932.